PROCESS / 03

FIELD GUIDE / Hitesh Plastics

Closure inspection

Define a defect set and verify the reject path as well as the image.

A camera can inspect a surface only if the handling and lighting make that surface visible. Start with the closure features that matter to sealing and opening, collect agreed good and defective samples, and document the inspection views. Acceptance must connect the detected sample to a verified reject. Use physical or package tests for requirements that the chosen optical setup cannot demonstrate.

Build an acceptance set

Starting pointWhat to check
Defect samplesDescribe the location, appearance and acceptance rule for each defect class.
Reject confirmationReconcile challenged, detected and rejected samples before releasing a recipe.

Detailed reading

For bottle cap vision inspection, read Bottle Cap Vision Inspection: Defect Samples and Acceptance Checks. It provides the detailed checks for this part of the decision.

These are source-based guides. Use the current supplier drawing and the approved package specification for a production release; the articles do not prescribe universal machine settings.